Output of each spray point
It must match the number of active nozzles, pump capacity and the required zone load.
Mist nozzles / atomisation
Orifice size, flow rate, spacing and spray direction must be selected for the system objective, airflow conditions and water quality.
The pump, filtration, pipework, controls and zone conditions all affect the final result.
From water supply to a controlled zone
The diagram shows functional relationships, not universal design values.
It must remain stable while all active zones are operating.
Filtration protects the precision flow passage and helps maintain a consistent spray pattern.
Component geometry affects the flow rate and the formation of the spray cone.
Droplets enter a zone where they interact with temperature, humidity and air movement.
Four design decisions
It must match the number of active nozzles, pump capacity and the required zone load.
Excessive spacing can create uneven coverage, while overly dense spacing increases water use unnecessarily.
The installation angle must account for wind, ventilation, open doors, obstructions and movement through the zone.
Controls can operate the system in pulses or by zone as conditions and operating objectives change.
Anatomy of a spray point
Stable operation requires mechanical compatibility, leak-tight connections, prepared water and regular inspection access.
The fitting must hold the spray direction and remain accessible for inspection.
It shapes the spray at the specified operating point.
The valve helps limit discharge after pressure in the line falls.
Nozzle condition is assessed from the spray pattern, leak tightness and operating history.
Conditions for stable operation
Warning signs
Maintenance cycle
Check the spray cone and nozzle behaviour after the zone stops.
Check filtration, pressure, connections and water quality.
Use a procedure appropriate to the component material and type of deposit.
Compare the spray point with the other nozzles in the zone.
Frequently asked questions
Parameters must always be assessed for the specific installation and site conditions.
No. The nozzle must work with the pressure, pump capacity, water quality and zone geometry. An undersized flow rate or unsuitable orifice can reduce stability and increase sensitivity to contamination.
The valve limits water discharge after pressure falls and provides a cleaner end to the cycle. It does not replace correct design, filtration or nozzle maintenance.
Frequency depends on water quality, duty, filtration and environmental conditions. The inspection schedule should be set for the specific installation from spray observations and component condition.
Not always. Zones can differ in installation height, airflow and required outcome, so one system may use different nozzle variants, spacing or spray directions.
Component selection for the system
Provide the system objective, number of zones, pump type, approximate line length and available water quality information.